Body composition in overweight and obese women postpartum: bioimpedance methods validated by dual energy X-ray absorptiometry and doubly labeled water

Författare och institution:
L. Ellegård (-); Fredrik Bertz (Institutionen för medicin, avdelningen för invärtesmedicin och klinisk nutrition); Anna Winkvist (Institutionen för medicin, avdelningen för invärtesmedicin och klinisk nutrition); I. Bosaeus (-); H.K. Brekke (-)
Publicerad i:
European Journal of Clinical Nutrition, Epub ahead of print
ISSN:
0954-3007
E-ISSN:
1476-5640
Publikationstyp:
Artikel, refereegranskad vetenskaplig
Publiceringsår:
2016
Språk:
engelska
Fulltextlänk:
Sammanfattning (abstract):
© 2016 Macmillan Publishers LimitedBackground/Objectives:Obesity, pregnancy and lactation all affect body composition. Simple methods to estimate body composition are useful in clinical practice and to evaluate interventions. In overweight and obese lactating women, such methods are not fully validated. The objective of this study was to validate the accuracy and precision of bioimpedance spectroscopy (BIS) by Xitron 4200 and 8-electrode multifrequency impedance (multifrequency bioimpedance analysis, MFBIA) by Tanita MC180MA with the reference methods dual energy X-ray absorptiometry (DXA) and doubly labeled water (DLW) for the assessment of body composition in 70 overweight and obese women postpartum.Subjects/Methods:The LEVA-study (Lifestyle for Effective Weight loss during lactation) consisted of an intervention and follow-up with three assessments at 3, 6 and 15 months postpartum, which made possible the validation of both accuracy and precision. Mean differences between methods were tested by a paired t-test and Bland–Altman plots for systematic bias.Results:At baseline, BIS and MFBIA underestimated fat mass (FM) by 2.6±2.8 and 8.0±4.2 kg compared with DXA (P<0.001) but without systematic bias. BIS and MFBIA overestimated total body water (TBW) by 2.4±2.2 and 4.4±3.2 kg (P<0.001) compared with DLW, with slight systematic bias by BIS. BIS correctly estimated muscle mass without systematic bias (P>0.05). BIS overestimated changes in TBW (P=0.01) without systematic bias, whereas MFBIA varied greatly and with systematic bias.Conclusions:BIS underestimates mean FM compared with DXA but can detect mean changes in body composition, although with large limits of agreement. BIS both accurately and precisely estimates muscle mass in overweight and obese women postpartum. MFBIA underestimates FM and overestimates TBW by proprietary equations compared with DXA and DLW.European Journal of Clinical Nutrition advance online publication, 30 March 2016; doi:10.1038/ejcn.2016.50.
Ämne (baseras på Högskoleverkets indelning av forskningsämnen):
MEDICIN OCH HÄLSOVETENSKAP ->
Klinisk medicin
MEDICIN OCH HÄLSOVETENSKAP ->
Hälsovetenskaper
MEDICIN OCH HÄLSOVETENSKAP ->
Hälsovetenskaper ->
Näringslära
Postens nummer:
240457
Posten skapad:
2016-08-19 11:56
Posten ändrad:
2016-08-19 13:50

Visa i Endnote-format

Göteborgs universitet • Tel. 031-786 0000
© Göteborgs universitet 2007