transparent gif

 

Ej inloggad.

Göteborgs universitets publikationer

Validity of hip-mounted uniaxial accelerometry with heart-rate monitoring vs. triaxial accelerometry in the assessment of free-living energy expenditure in young children: the IDEFICS Validation Study

Författare och institution:
Robert Ojiambo (-); Kenn Konstabel (-); Toomas Veidebaum (-); John Reilly (-); Vera Verbestel (-); Inge Huybrechts (-); Isabelle Sioen (-); José A Casajús (-); Luis A Moreno (-); German Vicente-Rodriguez (-); Karin Bammann (-); Bojan Tubić (Institutionen för kliniska vetenskaper, sektionen för kvinnors och barns hälsa, Avdelningen för pediatrik); Staffan Mårild (Institutionen för kliniska vetenskaper, sektionen för kvinnors och barns hälsa, Avdelningen för pediatrik); Klaas Westerterp (-); Yannis P Pitsiladis (-)
Publicerad i:
Journal of applied physiology (Bethesda, Md. : 1985), 113 ( 10 ) s. 1530-1536
ISSN:
1522-1601
Publikationstyp:
Artikel, refereegranskad vetenskaplig
Publiceringsår:
2012
Språk:
engelska
Fulltextlänk:
Sammanfattning (abstract):
One of the aims of Identification and Prevention of Dietary- and Lifestyle-Induced Health Effects in Children and Infants (IDEFICS) validation study is to validate field measures of physical activity (PA) and Energy expenditure (EE) in young children. This study compared the validity of uni-axial accelerometry with heart-rate (HR) monitoring vs. tri-axial accelerometry against doubly labeled water (DLW) criterion method for assessment of free-living EE in young children. 49 European children (25 female, 24 male) aged 4-10 years (mean age 7 ± 2 years) were assessed by uni-axial ActiTrainer with HR, uni-axial 3DNX and tri-axial 3DNX accelerometry. Total energy expenditure (TEE) was estimated using DLW over a 1 week period. The longitudinal axis of both devices and tri-axial 3DNX counts per minute (CPM) were significantly (P<0.05) associated with physical activity level (PAL) (r = 0.51 ActiTrainer, r = 0.49 uni-axial-3DNX and r = 0.42 tri-axial ∑3DNX). 86% of the variance in TEE could be predicted by a model combining body mass (Partial r(2) = 71%; P<0.05), CPM-ActiTrainer (Partial r(2) = 11%; P<0.05) and difference between HR at moderate and sedentary activities (ModHR - SedHR; Partial r(2) = 4%; P<0.05) The standard error (S.E) of TEE estimate for ActiTrainer and 3DNX models ranged from 0.44-0.74 MJ/d or approximately 7-11% of the average TEE. The S.E of activity-induced energy expenditure (AEE) model estimates ranged from 0.38-0.57 MJ/d or 24-26% of the average AEE. It is concluded that the comparative validity of hip-mounted uni-axial and tri-axial accelerometers for assessing PA and EE is similar.
Ämne (baseras på Högskoleverkets indelning av forskningsämnen):
MEDICIN OCH HÄLSOVETENSKAP ->
Klinisk medicin ->
Pediatrik
Nyckelord:
accelerometers; validity; young children; obesity; doubly labeled water
Postens nummer:
165894
Posten skapad:
2012-11-12 11:27
Posten ändrad:
2016-09-02 08:48

Visa i Endnote-format

Göteborgs universitet • Tel. 031-786 0000
© Göteborgs universitet 2007